E: info@deltapanels.com Head Office: 731 Boundary Road, Richlands, Qld 4077 +61 7 3271 2170 W: www.deltapanels.com Sydney Depot: 11 The Old Northern Road, Narellan, NSW 2567 +61 2 4611 7712 ABN: 11 147 861 292 Version Date: 2025-11-25 80 Flyover with SHS Upright (See Figure A37) Part List ITEM QTY PART NUMBER DESCRIPTION ITEM QTY PART NUMBER DESCRIPTION 1 2 65x65x1.6 SHS FLYOVER UPRIGHT SHS 6 4 DPP5736 BEAM SPACER 2 8 90064A580 TEK SCREW (SDS) 12-14x20 7 6 HEX BOLT M10x90 HEX BOLT M10x90 + NUT 3 1 DPB1002 2.5m DELTABEAM 8 6 HEXBOLT_STEEL_DIN931_ DIN931 HEX-HEAD BOLT M10x70 + NUT 4 2 DPP1226-X ADJUSTABLE FASCIA BRACKET 9 2 TIMBER TRUSS WALL TIMBER TRUSS WALL 5 2 DPP5706-P INTERNAL POST BRACKET (SUIT 65x65x1.6) Figure A37 STEP 9 CONNECTION TO HOUSE DETAIL A DETAIL B INTERNAL POST BRACKET BEAM SPACER HEX BOLT M10 x 90 + NUT HEX BOLT M10 x 90 + NUT ADJUSTABLE FASCIA BRACKET FLYOVER UPRIGHT SHS TEK SCREW (12-14x20) DELTA BEAMTM EXISTING TIMBER TRUSS THE USE OF STRAPS AND BRACKETS IS REQUIRED TO ENSURE THAT THE PLATE IS STRUCTURALLY CONNECTED TO THE ROOF STRUCTURE NOTE : A QUALIFIED ENGINEER IS REQUIRED TO CHECK THE STRUCTURAL INTEGRITY OF THE EXISTING ROOFING AND WALL SYSTEM. MAXIMUM SPACING 2000MM A MAXIMUM OF 100MM 100MM