ENGINEERING NOTES
GENERAL NOTES
The information contained in this Engineering & Construction Manual is specifically designed to suit the range of
freestanding and attached Delta Patio™ and Carports which have been engineered with an option of either Single
Skin or Insulated Roofs.
A Patio/Carport is considered to be a freestanding structure unless it’s attached to an existing structure for at least
50% of its shortest side.
The information contained in this Engineering manual relates specifically to products supplied by Delta Panels
Pty Ltd™. Any products not approved by Delta Panels Pty Ltd™ will void Engineering Approvals and Warranties
expressed or implied.
All assembly, connection and installation procedures must comply with the Delta Panels™ standards as set out in
the Engineering & Construction Manual
SITE SAFETY
It is the Builder/Owner’s responsibility to ensure that any existing structure that the Delta Patio/Carport is to be
attached to, is adequately reinforced to accommodate all additional loads created by the new Delta Patio/Carport.
Prior to any footings being commenced it is the Builder/Owner’s responsibility to ensure that the footings will not
impact on any existing underground services and facilities.
CONCRETE/FOOTINGS
For any connections to an existing concrete slab, it is the Builder/Owner’s responsibility to ensure that the slab is
structurally adequate to support the additional load.
- Concrete strength must be a minimum of N25 in accordance with AS 1379-2007.
- The slab must cover the full width of the roof and reinforced with F62 mesh or greater
- For footings with depth deeper than 500mm, reinforce the footings with 4 x Y12 Vertical rods - ties with
R6 LIGS500 centres.
- Hold down capacities apply to piers with an undercut into cohesive clay soils. They are not applicable
in sandy soils which must be referred to an Engineer.
STEEL COMPONENTS
All steel structural components of the Delta PanelsTM Patio & Carport systems are in accordance with these
Australian Standards:
DeltaSingleTM Steel Skin
AS 1397-2011
Delta Insulated Panel Top Skin
AS 1397-2011
Delta Insulated Panel Bottom Skin AS 1397-2011
Delta BeamsTM
AS 1397-2011
Posts (Square Hollow Sections)
AS 1163-2016
FIXINGS
ll fixing components of the Delta Panels™ Patio & Carport systems are in accordance with these Australian
Standards
Bolts shall be grade 4.6 or better
AS 1110.1-2015
Fixing Screws shall be class 3 AS 3566-2002