E: info@deltapanels.com Head Office: 731 Boundary Road, Richlands, Qld 4077 +61 7 3271 2170 W: www.deltapanels.com Sydney Depot: 11 The Old Northern Road, Narellan, NSW 2567 +61 2 4611 7712 ABN: 11 147 861 292 Version Date: 2025-11-25 57 STEP 7 POST TO FOOTING SELECTION Timber Post to Stirrup (see Figure A14) Tabulated Data is in kN Fixing Details Footing Details Number of Bolts and Diameter Uplift (kN) Depth of Pad d(mm) D=450mm (kN) D=600mm (kN) Depth of Pad d(mm) D=450mm (kN) D=600mm (kN) 2/M10 Bolts 6.75 600 2.25 3.99 1200 4.49 7.98 2/M12 Bolts 9.65 750 2.81 4.99 1500 5.61 9.98 2/M16 Bolts 16.7 900 3.37 5.99 1800 6.74 11.98 1000 3.74 6.65 2000 7.49 13.31 Figure A14