STEP 5        BEAM SPAN SELECTION
DELTABEAM STEEL - 250mm  SPAN TABLE
Single Span
Continuous Span
V sit,500
RLW
Type 1
Type 2
Type 3
Type 4
Type 1
Type 2
Type 3
Type 4
N1 
(W34)
900
12.0
12.0
12.0
12.0
12.0
12.0
12.0
12.0
1200
11.6
11.6
11.6
11.6
12.0
12.0
12.0
12.0
1500
10.9
10.9
10.7
10.9
12.0
12.0
12.0
12.0
1800
10.5
10.5
10.1
10.5
12.0
12.0
12.0
12.0
2100
10.1
10.1
9.6
10.1
12.0
12.0
12.0
12.0
2400
9.7
9.7
9.2
9.7
12.0
12.0
12.0
12.0
2700
9.4
9.4
8.8
9.4
11.9
11.9
11.9
11.9
3000
9.2
9.2
8.5
9.2
11.6
11.6
11.6
11.6
3600
8.8
8.8
8.0
8.8
11.1
11.1
10.9
11.1
4200
8.5
8.5
7.6
8.5
10.6
10.6
10.3
10.6
4800
8.2
8.2
7.3
8.2
10.3
10.3
9.9
10.3
5400
7.9
7.9
7.0
7.9
10.0
10.0
9.5
10.0
6000
7.7
7.7
6.8
7.6
9.7
9.7
9.2
9.7
N2
(W40)
900
12.0
12.0
11.3
12.0
12.0
12.0
12.0
12.0
1200
11.6
11.6
10.3
11.5
12.0
12.0
12.0
12.0
1500
10.9
10.9
9.5
10.7
12.0
12.0
12.0
12.0
1800
10.5
10.4
9.0
10.1
12.0
12.0
12.0
12.0
2100
10.1
9.9
8.5
9.6
12.0
12.0
11.6
12.0
2400
9.7
9.5
8.2
9.1
12.0
12.0
11.1
12.0
2700
9.4
9.1
7.8
8.8
11.9
11.9
10.7
11.9
3000
9.2
8.8
7.6
8.5
11.6
11.6
10.3
11.5
3600
8.8
8.3
7.1
8.0
11.1
11.1
9.7
10.8
4200
8.5
7.9
6.8
7.6
10.6
10.6
9.2
10.3
4800
8.2
7.5
6.5
7.3
10.3
10.2
8.6
9.8
5400
7.9
7.2
6.2
7.0
10.0
9.8
8.1
9.5
6000
7.7
7.0
6.0
6.7
9.7
9.5
7.7
9.1
N3/C1
(W50)
900
12.0
11.2
9.7
10.8
12.0
12.0
12.0
12.0
1200
11.5
10.1
8.8
9.8
12.0
12.0
11.9
12.0
1500
10.7
9.4
8.2
9.1
12.0
12.0
11.1
12.0
1800
10.1
8.9
7.7
8.6
12.0
12.0
10.4
11.6
2100
9.6
8.4
7.3
8.1
12.0
11.4
9.9
11.0
2400
9.2
8.0
7.0
7.8
12.0
10.9
9.5
10.6
2700
8.8
7.7
6.7
7.5
11.9
10.5
9.1
10.1
3000
8.5
7.5
6.5
7.2
11.5
10.1
8.6
9.8
3600
8.0
7.0
6.1
6.8
10.9
9.5
7.8
9.2
4200
7.6
6.7
5.8
6.5
10.3
9.0
7.3
8.6
4800
7.3
6.4
5.5
6.2
9.9
8.4
6.8
8.0
5400
7.0
6.1
5.3
5.9
9.5
7.9
6.4
7.5
6000
6.7
5.9
5.1
5.7
9.1
7.5
6.1
7.2
N4/C2
(W61)
900
11.0
9.7
8.4
9.4
12.0
12.0
11.4
12.0
1200
10.0
8.8
7.7
8.5
12.0
12.0
10.4
11.6
1500
9.3
8.2
7.1
7.9
12.0
11.1
9.6
10.7
1800
8.7
7.7
6.7
7.4
11.8
10.4
9.0
10.1
2100
8.3
7.3
6.4
7.1
11.2
9.9
8.4
9.6
2400
7.9
7.0
6.1
6.8
10.8
9.5
7.8
9.2
2700
7.6
6.7
5.8
6.5
10.3
9.1
7.4
8.7
3000
7.4
6.5
5.6
6.3
10.0
8.6
7.0
8.2
3600
6.9
6.1
5.3
5.9
9.4
7.9
6.4
7.5
4200
6.6
5.8
5.0
5.6
8.8
7.3
5.9
6.9
4800
6.3
5.5
4.8
5.4
8.2
6.8
5.5
6.5
5400
6.0
5.3
4.6
5.2
7.8
6.4
5.2
6.1
6000
5.8
5.2
4.4
5.0
7.4
6.1
4.9
5.8
N5/C3
(W74)
900
9.6
8.5
7.4
8.2
12.0
11.5
10.0
11.1
1200
8.7
7.7
6.7
7.5
11.8
10.5
9.1
10.1
1500
8.1
7.2
6.2
6.9
11.0
9.7
8.1
9.4
1800
7.6
6.7
5.9
6.5
10.3
9.1
7.4
8.7
2100
7.2
6.4
5.6
6.2
9.8
8.4
6.9
8.0
2400
6.9
6.1
5.3
5.9
9.4
7.9
6.4
7.5
2700
6.7
5.9
5.1
5.7
9.0
7.4
6.0
7.1
3000
6.4
5.7
4.9
5.5
8.5
7.1
5.7
6.7
3600
6.0
5.3
4.7
5.2
7.8
6.4
5.2
6.1
4200
5.7
5.1
4.3
4.9
7.2
6.0
4.8
5.7
4800
5.5
4.9
4.1
4.7
6.7
5.6
4.5
5.3
5400
5.3
4.7
3.8
4.5
6.3
5.3
4.3
5.0
6000
5.1
4.5
3.6
4.2
6.0
5.0
4.1
4.8
Deflection limits adopted are:
L/125 under serviceability wind (assumed 50% of ULS wind)
L/150 under maintenance load
L/300 under dead load (30kg/m of sheeting/panel + self-weight of beam is allowed)
DeltaBeam - Steel
Maximum Cantilever - 25% of the Span