E: info@deltapanels.com Head Office: 731 Boundary Road, Richlands, Qld 4077 +61 7 3271 2170 W: www.deltapanels.com Sydney Depot: 11 The Old Northern Road, Narellan, NSW 2567 +61 2 4611 7712 ABN: 11 147 861 292 Version Date: 2025-11-25 52 STEP 5 BEAM SPAN SELECTION DELTABEAM ALUMINIUM - 150mm SPAN TABLE Single Span Continuous Span V sit,500 RLW Type 1 Type 2 Type 3 Type 4 Type 1 Type 2 Type 3 Type 4 N1 (W34) 900 7.9 7.9 6.9 7.8 9.9 9.9 9.4 9.9 1200 7.3 7.3 6.3 7.1 9.2 9.2 8.5 9.2 1500 6.9 6.8 5.8 6.5 8.7 8.7 7.9 8.7 1800 6.6 6.4 5.5 6.2 8.3 8.3 7.4 8.3 2100 6.4 6.1 5.2 5.9 8.0 8.0 7.1 7.9 2400 6.2 5.8 5.0 5.6 7.7 7.7 6.8 7.6 2700 6.0 5.6 4.8 5.4 7.5 7.5 6.5 7.3 3000 5.8 5.4 4.6 5.2 7.3 7.3 6.3 7.1 3600 5.6 5.1 4.4 4.9 7.0 6.9 5.9 6.6 4200 5.3 4.8 4.1 4.6 6.7 6.5 5.6 6.3 4800 5.2 4.6 4.0 4.4 6.5 6.3 5.4 6.0 5400 5.0 4.4 3.8 4.3 6.3 6.0 5.2 5.8 6000 4.9 4.3 3.7 4.1 6.2 5.8 5.0 5.6 N2 (W40) 900 7.9 7.1 6.1 6.9 9.9 9.7 8.3 9.3 1200 7.3 6.5 5.6 6.2 9.2 8.8 7.6 8.5 1500 6.9 6.0 5.2 5.8 8.7 8.2 7.0 7.9 1800 6.5 5.7 4.9 5.5 8.3 7.7 6.6 7.4 2100 6.2 5.4 4.6 5.2 8.0 7.3 6.3 7.0 2400 5.9 5.1 4.4 5.0 7.7 7.0 6.0 6.7 2700 5.7 4.9 4.3 4.8 7.5 6.7 5.8 6.5 3000 5.5 4.8 4.1 4.6 7.3 6.5 5.6 6.2 3600 5.1 4.5 3.9 4.3 7.0 6.1 5.3 5.9 4200 4.9 4.3 3.7 4.1 6.6 5.8 5.0 5.6 4800 4.7 4.1 3.5 3.9 6.3 5.5 4.8 5.3 5400 4.5 3.9 3.4 3.8 6.1 5.3 4.6 5.1 6000 4.3 3.8 3.3 3.7 5.9 5.1 4.4 5.0 N3/C1 (W50) 900 6.9 6.1 5.2 5.9 9.3 8.2 7.1 7.9 1200 6.3 5.5 4.8 5.3 8.5 7.5 6.5 7.2 1500 5.8 5.1 4.4 4.9 7.9 6.9 6.0 6.7 1800 5.5 4.8 4.2 4.6 7.4 6.5 5.7 6.3 2100 5.2 4.6 4.0 4.4 7.0 6.2 5.4 6.0 2400 5.0 4.4 3.8 4.2 6.7 5.9 5.1 5.7 2700 4.8 4.2 3.6 4.1 6.5 5.7 4.9 5.5 3000 4.6 4.1 3.5 3.9 6.3 5.5 4.8 5.3 3600 4.3 3.8 3.3 3.7 5.9 5.2 4.5 5.0 4200 4.1 3.6 3.1 3.5 5.6 4.9 4.3 4.8 4800 3.9 3.5 3.0 3.3 5.4 4.7 4.1 4.5 5400 3.8 3.3 2.9 3.2 5.1 4.5 3.9 4.4 6000 3.7 3.2 2.8 3.1 5.0 4.4 3.8 4.2 N4/C2 (W61) 900 6.0 5.3 4.6 5.1 8.1 7.1 6.2 6.9 1200 5.4 4.8 4.2 4.6 7.4 6.5 5.6 6.3 1500 5.0 4.4 3.9 4.3 6.8 6.0 5.2 5.8 1800 4.7 4.2 3.6 4.0 6.4 5.7 4.9 5.5 2100 4.5 4.0 3.4 3.8 6.1 5.4 4.7 5.2 2400 4.3 3.8 3.3 3.7 5.8 5.1 4.5 5.0 2700 4.1 3.6 3.2 3.5 5.6 5.0 4.3 4.8 3000 4.0 3.5 3.1 3.4 5.4 4.8 4.2 4.6 3600 3.8 3.3 2.9 3.2 5.1 4.5 3.9 4.4 4200 3.6 3.1 2.7 3.0 4.8 4.3 3.7 4.1 4800 3.4 3.0 2.6 2.9 4.6 4.1 3.5 4.0 5400 3.3 2.9 2.5 2.8 4.5 3.9 3.3 3.8 6000 3.2 2.8 2.4 2.7 4.3 3.8 3.2 3.7 N5/C3 (W74) 900 5.2 4.6 4.0 4.5 7.1 6.2 5.4 6.0 1200 4.7 4.2 3.6 4.0 6.4 5.7 4.9 5.5 1500 4.4 3.9 3.4 3.8 6.0 5.3 4.6 5.1 1800 4.1 3.7 3.2 3.5 5.6 5.0 4.3 4.8 2100 3.9 3.5 3.0 3.4 5.3 4.7 4.1 4.6 2400 3.8 3.3 2.9 3.2 5.1 4.5 3.9 4.4 2700 3.6 3.2 2.8 3.1 4.9 4.3 3.8 4.2 3000 3.5 3.1 2.7 3.0 4.7 4.2 3.6 4.0 3600 3.3 2.9 2.5 2.8 4.5 3.9 3.4 3.8 4200 3.1 2.8 2.4 2.7 4.2 3.7 3.1 3.6 4800 3.0 2.6 2.3 2.5 4.0 3.6 2.9 3.4 5400 2.9 2.5 2.2 2.5 3.9 3.4 2.7 3.2 6000 2.8 2.5 2.1 2.4 3.8 3.2 2.6 3.1 Deflection limits adopted are: L/125 under serviceability wind (assumed 50% of ULS wind) L/150 under maintenance load L/300 under dead load (30kg/m of sheeting/panel + self-weight of beam is allowed) DeltaBeam - Aluminium Maximum Cantilever - 25% of the Span
View this content as a flipbook by clicking here.