COMPONENTS:
Flashings
Flashings unless otherwise noted are to be made from 0.55mm
steel and installed to AS 1562.1:2018. Aluminium can be used
but referral to IPCA for cold storage compliance is advised.
12. INSTALLATION - FASTENERS,
FLASHINGS, FOAM INFILLS STRIPS
AND SEALANTS
Foam Infill Strips
Butyl Rubber Adhesive Tape
for Metal Roofing
Sealant for Metal Roofing
The sealant should be of neutral cure and meet the recommendations
as outlined in BlueScope TB-9 Sealants for Exterior Finishes.
FM Approvals
For full installation details please visit FM Approvals RoofNav site - www.fmapprovals.com/RoofNav
11. INSTALLATION - FACTORY MUTUAL
INSTALLATION REQUIREMENTS -
PR 459387
To comply with the Factory Mutual Accreditation PR459387
the following conditions must be followed.
DeltaTrim-TPC™, DeltaOrb-TPC™ & DeltaCorroCorro-TPC™
Installation Requirements
Installation Detail
Fastening System A
Through-fastened with EJOT JT2-D-6-5,5/6,3xL fasteners spaced 250 mm (9.8 in) on
center at each support. Stitch screw EJOT COLORFAST CF15 SF 6,3x25 every 250 mm
(9.8 in) on overlapping seams.