11. INSTALLATION - FACTORY MUTUAL  
       INSTALLATION REQUIREMENTS -  
       PR 459387
Steel Angles/Channels
0.6mm Pre-Painted Steel Angles
 - 70/70mm
Fire-Rated Silicone
Fasteners
Rivets 
 - 4.8 x 12mm 304 grade stainless steel rivets
To comply with the Factory Mutual Accreditation PR459387 
the following conditions must be followed.
DeltaCool-TPC™ Installation Requirements
Interior Installations
Flashing - Minimum 70 x 70 x 0.6mm steel fasteners maximum 300mm on centre
Sealant/Gasket/Caulking - Silicone sealant applied at panel joints and flashings
Other - Interior panel slip joints are secured with steel blind rivets or steel screws 
300mm on centre
Exterior Installations
Fastening System B
Through-fastened with Delta Panels mushroom bolt fasteners spaced 600mm on centre 
at each support. Fasteners are  located 300mm from each panel edge.