DeltaDualCore™ Panel Awning Systems Revision 1-12 19 Sandwich Panel with Expanded Polystyrene (EPS) Core Test Report Test Specimen Relevant Performance 3. AS1530.3:1999 AWTA Test No. 19-003621 (refer to Section D.1) Pre-painted steel skins (DeltaOrb™) bonded to an EPS core with fire retardant. Indices: Ignitability: 0 Spread of Flame: 0 Heat Evolved: 0 Smoke Developed: 2 4. AS1530.3:1999 AWTA Test No. 19-003623 (refer to Section D.2) Pre-painted steel skins (DeltaTrim™) bonded to an EPS core with fire retardant. Indices: Ignitability: 0 Spread of Flame: 0 Heat Evolved: 0 Smoke Developed: 2 5. AS3959:2009 Branz Fire Assessment Report FC10893- 001 (refer to Appendix F) DeltaTrim™ and DeltaOrb™ steel facings (0.40 mm or 0.60 mm) with EPS core with thickness up to 150 mm thick. DeltaOrb™ - BAL40 DeltaTrim™ - BAL40 Coated Steel Facings Test Report Test Specimen Relevant Performance 6. AS1530.3:1999 CSIRO Report No. FNE11602 (refer to Section D.3) BlueScope ZINCALUME Steel (0.5 mm nominal thickness) Indices: Ignitability: 0 Spread of Flame: 0 Heat Evolved: 0 Smoke Developed: 2 7. AS1530.3:1999 CSIRO Report No. FNE11604 (refer to Section D.4) BlueScope COLORBOND steel (0.8 mm nominal thickness) Indices: Ignitability: 0 Spread of Flame: 0 Heat Evolved: 0 Smoke Developed: 2 8. AS1530.3:1999 CSIRO Report No. FNE11603 (refer to Section D.5) Bluescope COLORBOND Permagard Steel (0.7 mm nominal thickness) Indices: Ignitability: 0 Spread of Flame: 0 Heat Evolved: 0 Smoke Developed: 1 9. AS1530.3:1999 AWTA Test No. 19-002186 (refer to Section D.6) MagnaFlow Coated Steel Panel (nominal mass per unit density 7850 kg/m3) Indices: Ignitability: 0 Spread of Flame: 0
View this content as a flipbook by clicking here.