Spread of Fire 
DeltaTrim™DualCore™ & DeltaOrb™DualCore™ Panels meet the performance requirements of H3P1 Volume 2, NCC 2022 when installed in accordance with the 
DeltaDualCore_brochure_V24-08-22 and Section 4.4 (SOTERA Pty Ltd; Fire Engineers Report; DeltaDualCor™e Panel Class 10a Awning and Patio Roof System; Rev 1-10; Dated 
17/01/2023) as a Class 10a structure (awning or patio) attached or adjacent to a Class 1a building positioned directly adjacent to the site boundary (i.e. less than 900 mm from the 
site boundary). The comparative assessment has demonstrated qualitatively and quantitatively that the DeltaDualCore™ system (when installed to the requirements of Section 4.4 
(SOTERA Pty Ltd; Fire Engineers Report; DeltaDualCore™ Panel Class 10a Awning and Patio Roof System; Rev 1-10; Dated 17/01/2023) does not increase the risk of fire spread from 
or to an associated Class 1 building when compared to the DtS base case. Performance requirement H3P1 is satisfied. The assessment is compliant in accordance with A2G2 (1)(b) 
and A2G2(2)(d). 
 
Source: SOTERA Pty Ltd; Fire Engineers Report; DeltaDualCore™ Panel Class 10a Awning and Patio Roof System; Rev 1-10; Dated 17/01/2023. 
A4 Manufacturer and manufacturing plant(s) 
Delta Panels Pty Ltd 
731 Boundary Road, 
Richlands, QLD 4077. 
A5 Installation requirements 
Installation must be in accordance with the DeltaDualCore_brochure_V24-07-03 
A6 Other relevant technical data 
No other relevant technical data. 
APPENDIX B – EVALUATION STATEMENTS 
B1 Evaluation methods 
1. 
Spread of Fire Provisions A5.2(1)(e). A report from a professional engineer. 
B2 Reports 
The below reports outline the compliance of the DeltaTrim™ DualCore™ & DeltaOrb™ DualCore™ in relation to the Spread of fire Properties as required by H3P1(1) 
1. 
SOTERA Pty Ltd; Fire Engineers Report No. A21007 J001 Rev 1-10; DeltaDualCore™ Panel Class 10a Awning and Patio Roof System; Rev 1-10; Dated 17/01/2023. Provides Compliance with H3P1(1). 
2. 
AWTA; NATA Accreditation No. 1356; Test No. 19-003619; Testing in accordance with AS/NZS 1530.3-1999; Dated 30/07/2019. Contributes towards Compliance with H3P1(1) 
3. 
CSIRO Certificate of Test: AS1530.3-1999 fire test certificate for Bluescope COLORBOND Metalic Steel Polyester, Report No. FNE11605; Dated 11/02/2016. Contributes towards Compliance with H3P1(1) 
4. 
CSIRO Certificate of Test: AS1530.3-1999 fire test certificate for UniCote pre-painted steel sheeting, Report No. FNE11809A; Dated 12/10/2016. Contributes towards Compliance with H3P1(1) 
5. 
CSIRO Certificate of Test: AS1530.1-1994 fire test certificate for Mineral Wool / Rockwool, Report No. FNC12604; Dated 08/07/2020. Contributes towards Compliance with H3P1(1) 
6. 
AWTA Product Testing: AS1530.3-1999 Test Report for DeltaTrim-EPS-FR, Test Number 19-003623; Dated 31/07/2019. Contributes towards Compliance with H3P1(1) 