Richard Donarski - CMI
Don Grehan – Unrestricted Building Certifier
Date of issue:
11/09/2024
Date of expiry:
28/09/2027
Certificate number: CM40330-I02-R00
This certificate is only valid when reproduced in its entirety.
Page 1 of 4
Certification Body:
ABN: 81 663 250 815
JAS-ANZ Accreditation
No. Z4450210AK
PO Box 273,
Palmwoods Qld 4555
Australia
P: +61 7 5445 2199
www.cmicert.com.au
office@cmicert.com.au
Certificate Holder:
Delta Panels Pty Ltd
ABN: 11 147 861 292
731 Boundary Road,
Richlands, QLD, 4077
Australia
Ph: 07 3271 2170
www.deltapanels.com.au
Certificate number: CM40330
THIS IS TO CERTIFY THAT
DeltaTrim™ DualCore™ & DeltaOrb™ DualCore™ Panels
Type and/or use of product:
Roof panel for Non-Habitable Buildings and Structures are situated within 900mm of a site
boundary and attached or adjacent to a Class 1a building.
Description of product:
Two pre-painted, roll-formed steel DeltaTrim™ or DeltaOrb™ skins bonded to a Mineral Wool
(minimum coverage 900mm) and fire retardant SL Grade Expanded Polystyrene core (EPS). Refer A2
for more information.
COMPLIES WITH THE FOLLOWING BCA PROVISIONS AND STATE OR TERRITORY VARIATION(S)
BCA 2022
Volume One
Volume Two
Performance Requirement(s):
Not Applicable
H3P1(1)
Will contribute to Spread of fire subject to the Limitations and
conditions below.
Deemed-to-Satisfy Provision(s): Not Applicable
Not Applicable
State or territory variation(s):
Not Applicable
Not Applicable
SUBJECT TO THE FOLLOWING LIMITATIONS AND CONDITIONS AND THE PRODUCT TECHNICAL DATA IN APPENDIX A AND EVALUATION STATEMENTS IN APPENDIX B
Limitations and conditions:
1.
Compliance with Contributes towards Compliance with H3P1(1) is subject to site specific performance solution to the satisfaction of the Appropriate Authority as described
by the NCC.
2.
The portion of the roof system which is located within 900 mm of a site boundary shall consist solely of non-combustible components (subject to (d)) including:
i.
Mineral wool
ii.
Pre-finished steel sheeting with combustible surface finish not exceeding 1 mm thickness and with a spread of flame index no greater than 0 in accordance with
NCC Clause H3D3.
iii.
Steel fixtures, gutters and the like
iv.
Steel columns, beams, purlins and the like
v.
Metallic flashing
b.
As the DeltaDualCore™ panel constitutes a bonded laminate, the following restrictions shall apply to the portion of the panel that is within 900mm of the site boundary:
i.
The laminas shall be restricted to steel facings with mineral wool core, each of which has been tested to AS 1530.1 and are deemed non-combustible.
ii.
Each adhesive layer may not exceed 1 mm in thickness and the total combined thickness of adhesive layers may not exceed 2mm.
iii.
The spread of flame index and the smoke developed index of the bonded laminated material as a whole shall not exceed 0 and 3 respectively.
Building classification/s:
Class 10a