Certificate number: CM40330-I02-R00
This certificate is only valid when reproduced in its entirety.
Page 3 of 4
APPENDIX A – PRODUCT TECHNICAL DATA
A1 Type and intended use of product
As per page 1.
A2 Description of product
DeltaTrim™DualCore™ & DeltaOrb™DualCore™ Panels consist of a top skin consisting of 0.45mm Colorbond® Steel and a bottom skin consisting of 0.55mm UniCote® Steel. The panels are available in a thickness
of 75mm, 100mm, 125mm or 150mm and 1000mm wide in various lengths. DeltaTrim™DualCore™ & DeltaOrb™DualCore™ Panels consist of a Mineral Wool section (minimum coverage 900mm) and fire retardant
SL Grade Expanded Polystyrene core (EPS) covers the remainder of the panel.
DeltaOrb™DualCore™
DeltaTrim™DualCore™
DeltaTrim™DualCore™ Fixing Details
Crest fixing only. One fixing every second crest
DeltaOrb™DualCore™ Fixing Details
Crest fixing only. One fixing every second crest
Panel Thickness
Fixing into Steel
Fixing into Timber
Panel Thickness
Fixing into Steel
Fixing into Timber
75mm
Tek 14 x 150mm Hex Head Screw
T17 14 x 150mm Hex Head Screw
75mm
Tek 14 x 135mm Hex Head Screw
T17 14 x 150mm Hex Head Screw
100mm
Tek 14 x 175mm Hex Head Screw
T17 14 x 175mm Hex Head Screw
100mm
Tek 14 x 150mm Hex Head Screw
T17 14 x 175mm Hex Head Screw
125mm
Tek 14 x 200mm Hex Head Screw
T17 14 x 200mm Hex Head Screw
125mm
Tek 14 x 175mm Hex Head Screw
T17 14 x 200mm Hex Head Screw
150mm
Tek 14 x 230mm Hex Head Screw
T17 14 x 230mm Hex Head Screw
150mm
Tek 14 x 200mm Hex Head Screw
T17 14 x 230mm Hex Head Screw
Use Cyclone Plate and Neo Washer on each fixing. Upon Installation the overlap needs to be stitch screwed or riveted every 300mm.
Roof Pitch
DeltaTrim™DualCore™ ≥ 2° and DeltaOrb™DualCore™ ≥ 3°.