Certificate number: CM40309-I03-R00 This certificate is only valid when reproduced in its entirety. Page 5 of 7 A3 Product specification Fire Hazard Properties C2D11(1)(i) Ignitability Index Spread of Flame Index Heat Evolved Index Smoke Developed Index Group Number Classification Delta CorroCorro EPS-FR, pre-painted steel skins bonded to an EPS core with fire retardant. | Core Density 13.5kgm3 0 0 0 0-1 Group 1 TPC, pre-painted steel skins bonded to a Thermosetting Phenolic Composite core. | Core Density 36kgs/m3 0 0 0 3 Group 1 Delta Trim EPS-FR, pre-painted steel skins bonded to an EPS core with fire retardant. | Core Density 13.5kgm3 0 0 0 2 Group 1 TPC, pre-painted steel skins bonded to a Thermosetting Phenolic Composite core. | Core Density 36kgs/m3 0 0 0 1 Group 1 Delta TrimTrim EPS-FR, pre-painted steel skins bonded to an EPS core with fire retardant. | Core Density 13.5kgm3 0 0 0 3 Group 1 TPC, pre-painted steel skins bonded to a Thermosetting Phenolic Composite core. | Core Density 36kgs/m3 0 0 0 1 Group 1 Delta TrimCorro- EPS-FR, pre-painted steel skins bonded to an EPS core with fire retardant. | Core Density 13.5kgm3 0 0 0 0-1 - TPC, pre-painted steel skins bonded to a Thermosetting Phenolic Composite core. | Core Density 36kgs/m3 0 0 0 3 - Delta Orb EPS-FR, pre-painted steel skins bonded to an EPS core with fire retardant. | Core Density 13.5kgm3 0 0 0 2 Group 1 TPC, pre-painted steel skins bonded to a Thermosetting Phenolic Composite core. | Core Density 36kgs/m3 0 0 0 0-1 Group 1 The specimens were tested in accordance with Specification 3 & 7 – Fire Hazard Properties, however no perforations, recesses or the likes were tested and sit outside of the scope of certification. Bushfire Attack Level (BAL) For the purpose of building regulations in Australia, the test specimen achieved a Bushfire Attack Level (BAL) of AA29. This report details the methods of construction, the test conditions and the results obtained when the specific element of construction described herein was tested in accordance with the test method of AS 1530.8.1. NOTE: Bushfire Attack Level (BAL) results are limited to the TPC core panel only. Source: CSIRO (Infrastructure Technologies); Report titled Bushfire test on a roof system, dated 21/12/2023 Roof Covering / Cladding The products described as DeltaOrb & DeltaTrim when installed at a roof pitch of five degrees or more, complies with the requirements of AS1562.1:2018- Design and Installation of Metal Roof and Wall Cladding Metal. It follows that the compliance with AS1562.1:2018 then satisfies the requirements of the Building Code of Australia 2022 Volume One deemed to satisfy provision F3D2(b) – Roof Covering and Volume Two deemed to satisfy provision H2D6(4) – Roof Cladding & H1D7 – Sheet Roofing. Source: Summermore Pty Ltd; Report titled WEATHER TIGHTNESS CERTIFICATION, dated 30/4/2024.
View this content as a flipbook by clicking here.