Certificate number: CM40309-I03-R00 
This certificate is only valid when reproduced in its entirety. 
Page 2 of 7 
 
2. 
In the absence of a site-specific performance solution, this system is not suitable for use in or on Class 2 to 9 buildings where BCA requires roof coverings to be 
non-combustible. 
3. 
In the absence of a site-specific performance solution, this product or system must not be used to facilitate the exemptions for a carport specified in Part 9.2.8 
Open Carports of the ABCB Housing Provisions.  
4. 
Any penetrations made into the certified products will void all nominated structural performance and Fire Hazard Properties. The adequacy of the size, location 
and spacing of any penetrations through the roof panel must be confirmed by a structural and fire engineer. 
5. 
It is the responsibility of the building designer to ensure fitness for purpose including, but not limited to, consideration for the corrosion resistance level of the 
product and the proximity to breaking surf. 
6. 
When being used for BAL applications the allowed maximum panel span between supports is limited to 1500mm as per the tested specimen, see A3 for details. 
7. 
The structural support members are designed and engineered separately as per project requirements by building designers and engineers. 
8. 
Installation must be in accordance with the following documentation: 
• 
Handling & Installation Manual Delta Panels Roofing Systems V2025.12.01.  
• 
Module A - Awnings, Patios & Carports Engineering & Construction Manual Non Cyclonic & Cyclonic Regions Doc 180509 V2025-11-25. 
• 
Flashings - Recommended Installation Doc 180520 V.23-10-27. 
9. 
Thermal Values listed in A3 have been verified as compliant on a contributes to basis, excluding the 100mm, which is deemed compliant.  
10. The building designer and installer must provide allowances for thermal expansion according to AS1562.1:2018 and other relevant design codes. 
11. Other than the items and information listed, the remainder of the information contained in the product’s literature is outside the Scope of Certification. 
12. The use of the certified product/system is subject to these Limitations and Conditions and must be read in conjunction with the Scope of Certification below. 
 
 
 
Scope of certification: The CodeMark Scheme is a building product certification scheme. The rules of the Scheme are available at the ABCB website www.abcb.gov.au. This Certificate of Conformity is to confirm that the relevant 
requirements of the Building Code of Australia (BCA) as claimed against have been met. The responsibility for the product performance and its fitness for the intended use remain with the Certificate Holder. The certification is not 
transferrable to a manufacturer not listed on Appendix A of this certificate. 
Only criteria as identified within this Certificate of Conformity can be used for CodeMark certification claims. Where other claims are made in a client’s Installation Manual, Website or other documents that are outside the criteria on this 
Certificate of Conformity, such criteria cannot be used or claimed to meet the requirements of this CodeMark certification.  
The NCC defines a Performance Solution as one that complies with the Performance Requirements by means other than a Deemed-to-Satisfy Solution. A Building Solution that relies on a CodeMark Certificate of Conformity that certifies a 
product against the Performance Requirements cannot be considered as Deemed-to-Satisfy Solution. 
This Certificate of Conformity may only relate to a part of a Performance Solution. In these circumstances other evidence of suitability is needed to demonstrate that the relevant Performance Requirements have been met. The relevant 
provisions of the Governing Requirements in Part A of the NCC will also need to be satisfied. 
This Certificate of Conformity is issued based on the evidence of compliance as detailed herein. Any deviation from the specifications contained in this Certificate of Conformity is outside of this document’s scope and the installation of the 
certified product will not be covered by this Certificate of Conformity.  
Disclaimer: The Scheme Owner, Scheme Administrator and Scheme Accreditation Body do not make any representations, warranties or guarantees, and accept no legal liability whatsoever arising from or connected to, the accuracy, 
reliability, currency or completeness of any material contained within this certificate; and the Scheme Owner, Scheme Administrator and Scheme Accreditation Body disclaim to the extent permitted by law, all liability (including 
negligence) for claims of losses, expenses, damages and costs arising as a result of the use of the product(s) referred to in this certificate. 
When using the CodeMark logo in relation to or on the product/system, the Certificate Holder makes a declaration of compliance with the Scope of Certification and confirms that the product is identical to the product certified herein. In 
issuing this Certificate of Conformity, CMI Certification Pty Ltd (CMI) has relied on the experience and expertise of external bodies (laboratories and technical experts). 
Nothing in this document should be construed as a warranty or guarantee by CMI, and the only applicable warranties will be those provided by the Certificate Holder. 
 