Glen Gugliotti – CMI 
 
Don Grehan – Unrestricted Building Certifier 
Date of issue:  
16/12/2025 
 
 
Date of expiry:  
16/12/2028 
Certificate number: CM40309-I03-R00 
This certificate is only valid when reproduced in its entirety. 
Page 1 of 7 
 
 
Certification Body: 
ABN: 81 663 250 815 
JAS-ANZ Accreditation 
No. Z4450210AK 
PO Box 273, 
Palmwoods Qld 4555 
Australia 
P: +61 7 5445 2199 
www.cmicert.com.au  
office@cmicert.com.au  
 
Certificate Holder: 
 
Delta Panels Pty Ltd 
ABN: 11 147 861 292 
731 Boundary Road, 
Richlands, QLD, 4077  
Australia 
Ph: 07 3271 2170 
www.deltapanels.com.au  
 
 
 
 
 
 
 
Certificate number: CM40309 
THIS IS TO CERTIFY THAT 
Delta Panels 
Type and/or use of product: 
Insulated roof panel. 
Description of product:  
Two pre-painted, roll-formed steel skins bonded to either a retardant grade Expanded Polystyrene 
core (EPS) or a Thermosetting Phenolic Composite (TPC). Refer A2 for more information. 
COMPLIES WITH THE FOLLOWING BCA PROVISIONS AND STATE OR TERRITORY VARIATION(S) 
BCA 2022 (Amdt. 2) 
 
Volume One 
Volume Two 
Performance Requirement(s): 
Not Applicable 
Not Applicable 
Deemed-to-Satisfy Provision(s): B1D4(j)(iv) 
Determination of structural resistance of materials and 
forms of construction - Refer Limitation and Condition 
7 & 8 
H1D7(2)(a)(i) 
Roof and wall cladding - Refer Limitation and Condition 7 
& 8 
 
C2D11(1)(i) 
Fire resistance - Fire hazard properties - Other 
materials – Limited to the 100mm EPS core panels – 
Refer Limitation and Condition 4 and A3 for details. 
H2D6(4) 
Roof and wall cladding - Refer Limitation and Condition 8 
 
F3D2(b) 
Roof coverings - Refer Limitation and Condition 8 
H7D4 
Construction in bushfire prone zone - Refer Limitation and 
Condition 6 
 
G5D3 
Construction in bushfire prone zone – TPC Core panel 
only - Refer Limitation and Condition 6 
H6D2 
Energy Efficiency – Roofs - Restricted to core – Refer 
Limitation and Condition 9 
 
J4D4 
Energy efficiency – Roofs - Restricted to core - Refer 
Limitation and Condition 9 
 
 
State or territory variation(s):  
C2D11 NSW, Vic. G5D3 (NSW), Part J (NT) 
H6D2 Vic, H7D4 (NSW, QLD & SA) 
SUBJECT TO THE FOLLOWING LIMITATIONS AND CONDITIONS AND THE PRODUCT TECHNICAL DATA IN APPENDIX A AND EVALUATION STATEMENTS IN APPENDIX B 
Limitations and conditions: 
1. 
This product has not been tested in accordance with AS 1530.1-1994 for non-combustibility. 
Building classification/s: 
Class 1,2,3,4,5,6,7,8,9 & 10 

View this content as a flipbook by clicking here.