DELTA PATIO & ROOFING RANGE
Use Cyclone Plate and Neo Washer on each fixing
Upon Installation the overlap needs to be stitch screwed or riveted every 300mm.
* Please refer to the web page for the available colour range, paint
finishes and relevant warranty conditions.
Early Fire Hazard Properties AS 1530-1999
DeltaTrim™-EPS-FR Panel
AWTA Test Report 18-006076 14-11-2018
Index
Test Range
External Top Skin
Ignitability
0-20
0
Spread of Flame
0-10
0
Heat Evolved
0-10
0
Smoke Developed
0-10
2
DeltaTrimTM Fixing Details
Crest fixing only. One fixing every second crest
Panel
Thickness
(mm)
Fixing into Steel
Fixing into Timber
50
Tek 14 x 135
Hex Head Screw
T17 14 x 125
Hex Head Screw
75
Tek 14 x 150
Hex Head Screw
T17 14 x 150
Hex Head Screw
100
Tek 14 x 175
Hex Head Screw
T17 14 x 175
Hex Head Screw
125
Tek 14 x 200
Hex Head Screw
T17 14 x 200
Hex Head Screw
150
Tek 14 x 230
Hex Head Screw
T17 14 x 230
Hex Head Screw
175
Tek 14 x 260
Hex Head Screw
T17 14 x 265
Hex Head Screw
200
Tek 14 x 260
Hex Head Screw
T17 14 x 300
Hex Head Screw
Detail A
Exposure to the External Surface - AS 3959-2009
Branz Fire Test Certificate FC10893-01-02-C1
Bushfire Attack Levels (BAL)
DeltaTrim-TPC achieved a Bushfire Attack Level (BAL) of AA29,
as per CSIRO report Number FSZ 2411 issued 21-12-2023,
when tested in accordance with the test method As 1530.8.1
DeltaTrimTM Acoustic Values
Acoustic Testing has been performed in compliance with
the requirements of AS 1191-2002 “Acoustics - Method
for Laboratory Measurement of Airborne Sound Insulation
of Building Elements”.
The procedures specified by AS 1276-1979 and AS/
NZS ISO 717.1:2004 were used to calculate the Sound
Transmission Class (STC) and the Weighted Sound
Reduction Index Rw = 25 dB.
Handling & Installation
DeltaTrim-EPS-FR & DeltaTrim-TPC are classified as
trafficable when used for maintenance purposes. The
following recommendations should be observed at all
times.
Recommendations
• Wear flat, rubber soled shoes
• Walk over the roof supporting beams
• Spread your weight over as many roof crests as possible
• Crawl boards should be used when accessing
areas not supported by a structure
DeltaTrim-MW core material is fibrous as such it is easy
to fracture the mineral wool fibres if handled and installed
incorrectly. Please ensure that correct lifting equipment
is used when the panels are transported and lifted into
position. Refer to the Handling & Installation Manual -
Roof Systems for the correct Crane & Sling Procedures.
Colour Chart - Warranty
Expanded Polystyrene Fire-Retardant Grade (EPS-FR)
is a thermoplastic that when exposed to high levels of
sustained heat is subject to changes in its structural
properties. On extremely hot days with no cooling wind,
dark colours have been recorded as reaching extreme
temperatures. The manufacturer of the steel recom-
mends the following colours, subject to conditions of
use, will maintain a temperature under 78.0oC dry heat
(see clause 9, sub-clause j of our product Warranty).
Please refer to Clause 12 of the Warranty – Roof Prod-
ucts for full details.
• Off White / Surfmist ®
• Gull Grey / Shale Grey TM
• Merino / Paperbark ®
• Mist Green / Paperbark ®
• Smooth Cream / Classic Cream TM
• Hamptons White
• Zinc
• Birch / Dune ®
• Armour Grey / Windspray
To maintain Warranty cover with dark colours it is
therefore recommended that a Thermosetting Phenolic
Composite (TPC) or Mineral Wool (MW) core be used for
all colours not listed above.
® Colour names are registered trademarks of Bluescope Steel Limited
TM Colour names are trademarks of Bluescope Steel Limited
View this content as a flipbook by clicking here.