Delta MW and EPS-FR Panel Awning and Patio Roof System Revision 1-4 16 Smoke Developed: 3 Sandwich Panel with Expanded Polystyrene (EPS-FR) Core Test Report Test Specimen Relevant Performance 4. AS1530.3:1999 AWTA Test No. 19-003621 (refer to Section D.1) Pre-painted steel skins (DeltaOrbâ„¢) bonded to an EPS-FR core with fire retardant. Indices: Ignitability: 0 Spread of Flame: 0 Heat Evolved: 0 Smoke Developed: 2 5. AS1530.3:1999 AWTA Test No. 19-003623 (refer to Section D.2) Pre-painted steel skins (DeltaTrimâ„¢) bonded to an EPS-FR core with fire retardant. Indices: Ignitability: 0 Spread of Flame: 0 Heat Evolved: 0 Smoke Developed: 2 6. INTENTIONALLY LEFT BLANK Coated Steel Facings Test Report Test Specimen Relevant Performance 7. AS1530.3:1999 CSIRO Report No. FNE11602 (refer to Section D.5) BlueScope ZINCALUME Steel (0.42 mm nominal thickness) Indices: Ignitability: 0 Spread of Flame: 0 Heat Evolved: 0 Smoke Developed: 2 8. AS1530.3:1999 AWTA Test No. 19-002186 (refer to Section D.6) MagnaFlow Coated Steel Panel (nominal mass per unit density 7850 kg/m3) Indices: Ignitability: 0 Spread of Flame: 0 Heat Evolved: 0 Smoke Developed: 3 9. AS1530.3:1999 CSIRO Report No. FNE11809A (refer to Section D.7) UniCote steel (0.55 mm nominal thickness) Indices: Ignitability: 0 Spread of Flame: 0 Heat Evolved: 0 Smoke Developed: 2 10. AS1530.3:1999 AWTA Test No. 20-000776 (refer to Section D.8) UniZinc (low carbon steel) Rigid Panel (< 1 mm nominal thickness) Indices: Ignitability: 0 Spread of Flame: 0 Heat Evolved: 0 Smoke Developed: 0-1
View this content as a flipbook by clicking here.