DeltaOrb-MW Fixing Details Crest fixing only. One fixing every second crest Panel Thickness (mm) Fixing into Steel Fixing into Timber 75 Tek 14 x 135 Hex Head Screw T17 14 x 150 Hex Head Screw 100 Tek 14 x 150 Hex Head Screw T17 14 x 175 Hex Head Screw 125 Tek 14 x 175 Hex Head Screw T17 14 x 200 Hex Head Screw 150 Tek 14 x 200 Hex Head Screw T17 14 x 230 Hex Head Screw SPECIFICATIONS - M W - M W Detail A Handling & Installation DeltaOrb-MW core material is fibrous as such it is easy to fracture the mineral wool fibres if handled and installed incorrectly. Please ensure that correct lifting equipment is used when the panels are transported and lifted into position. Refer to the Handling & Installation Manual - Roof Systems for the correct Crane & Sling Procedures. When installing Mineral Wool panels only step onto the section of the panels that are supported by the underneath roof structure. Do not step on unsupported spans. Once installed it is classified as trafficable for maintenance purposes only and all traffic should only be on the supported roof sections. Use Cyclone Plate and Neo Washer on each fixing. Upon Installation the overlap needs to be stitch screwed or riveted every 300mm. Please refer to the web page for the available colour range, paint finishes and relevant warranty conditions. DeltaOrb-MW Acoustic Values Frequency 50mm 125mm 100 15.41 15.00 160 16.40 15.09 200 18.81 17.70 250 19.70 18.51 315 21.39 19.40 400 22.31 19.69 630 23.40 19.10 800 23.69 17.31 1000 25.61 18.29 1250 21.01 30.10 1600 20.00 36.19 2000 34.79 37.30 2500 41.70 37.09 3150 44.10 35.69 5000 44.61 39.90 STC 24.00 23.00 RW 25.00 24.00 Early Fire Hazard Properties AS 1530.3:1999 AWTA Test Report 21-003529 19/07/21 Index Test Range External Top Skin Ignitability 0-20 0 Spread of Flame 0-10 0 Heat Evolved 0-10 0 Smoke Developed 0-10 3 As at the stated Version Date all of the information contained in this document is correct. Please check on our WebPage to ensure that you’re referencing the current version. Delta Panels Pty Ltd - ABN: 11 147 861 292 E: info@deltapanels.com W: www.deltapanels.com Head Office: 731 Boundary Road, Richlands, Qld 4077 P: +61 07 3271 2170 Sydney Depot: 11 The Old Northern Road, Narellan, NSW 2567 P: +61 02 4611 7712 Version Date: 2025-12-04 DeltaOrb-MW Spanning Recommendation Due to the friable nature of Mineral Wool we recommend that the maximum unsupported spanning is:- 75mm - 2500mm 100mm - 2500mm 125mm - 3000mm 150mm - 3000mm Acoustic Values Acoustic Testing has been performed in compliance with the requirements of AS 1191-2002 “Acoustics - Method for Laboratory Measurement of Airborne Sound Insulation of Building Elements”. The procedures specified by AS/NZS ISO 717.1:2024 were used to calculate the Sound Transmission Class (STC) and the Weighted Sound Reduction Index Rw = 25 dB.
View this content as a flipbook by clicking here.