DeltaOrb-MW is an Insulated Roof Panel System, comprising of two pre-painted, roll-formed steel skins, with a roll-formed steel skins bonded to a non-combustible mineral wool core. CodeMark Australia Certificate CM40345 DeltaFireX Car Port System incorporating DeltaOrb-MW panels certifies compliance with the stated performance provisions of the NCC 2022 Amendment 2. Please refer to the certificate, as displayed on our web page, for the exact details of the compliance. CodeMark Australia Certificate CM40346 Class 10a Awning and Patio Roof System incorporating DeltaOrb-MW and DeltaOrb-EPS panels certifies compliance with the stated performance provisions of the NCC 2022 Amendment 2. Please refer to the certificate, as displayed on our web page, for the exact details of the compliance. Steel Skin Details Top Skin 0.42mm / G550 AZ150 Bottom Skin 0.55mm / G300 Z275 Max. Skin Temperature 78oC Dry Heat Core Material Details Mineral Wool Thermal Conductivity AS 1366.2/ASTM C 518 0.0365 W/mK @23.0oC Core Density 100kg/m3 0.6mm Skin Weight (kg/ m2) 75mm Panel 18.50 100mm Panel 21.00 125mm Panel 23.50 150mm Panel 26.00 R Value (m2.K/W) AS/NZS 4859 Parts 1 & 2:2018 Thickness Winter (15o) Summer (30o) 75mm Panel 2.50 2.35 100mm Panel 3.20 3.00 125mm Panel 3.90 3.70 150mm Panel 4.60 4.35 Certificate of Conformity CM40435 & CM40436 Sheet Coverage 1000mm Length (mm) Cut to Length Min of 1800mm Length Tolerance (mm) 5mm+/- Thickness (mm) 75, 100, 125, 150 Minimum Roof Pitch Building Classes 1-9 - 5º Building Class 10 - 3º Flatness Standards 0.40mm 0.60mm Surface deformations can be apparent to the naked eye when observed in certain lighting conditions SPECIFICATIONS - M W - M W Detail A Detail B Combustibility Test AS 1530.1-1994 CSIRO Report no. FNC12604 dated 8/7/2020 tested five (5) samples of the Delta Panels supplied mineral wool sample and certified that the material is NOT deemed combustible according to the criteria specified in clause 3.4 of AS 1530.1-1994. Sotera - FireX™ Car Port System The Sotera report A21007 J005 - DeltaFireX Car Port System FER dw rev 1-4 (NOTE REV 1-4) confirms that the FireX™ Car Port System meets the performance requirements of H3P1 Volume 2, NCC 2022 Amendment 2 when installed in accordance with the DeltaFireXRoof Brochure version V25.12.04 and section 4.4 of their report as a Class 10a structure (car port) attached or adjacent to a Class 1a building positioned directly adjacent to the site boundary (i.e.) less than 900 mm from the site boundary) Sotera - Delta MW and EPS-FR Awning & Patio Roof System The Sotera report A21007 J004 - Delta MW and EPS-FR Awning and Patio Roof System FER dw rev 1-4, confirms that the Mineral Wool & EPS-FR Awning & Patio Roof System meets the performance requirements of H2P1 Volume 2, NCC 2022 Amendment 2 when installed in accordance with the Delta Mineral Wool Panels Brochure version V25.12.04 and section 4.4 of their report as a Class 10a structure (car port) attached or adjacent to a Class 1a building positioned directly adjacent to the site boundary (i.e.) less than 900 mm from the site boundary) Delta Panels Pty Ltd - ABN: 11 147 861 292 E: info@deltapanels.com W: www.deltapanels.com Head Office: 731 Boundary Road, Richlands, Qld 4077 P: +61 07 3271 2170 Sydney Depot: 11 The Old Northern Road, Narellan, NSW 2567 P: +61 02 4611 7712 Version Date: 2025-12-04 Fire Test Certificate - AS ISO 9705 Group 1 Classification in accordance with NCC 2022 Volume One Amendment 2 Clause C2D11 & Clause S7C4 determined in accordance with AS 5637.1:2015 as per Jensen Hughes test report 252674 issued 28 November 2025 & Spectra Fire Engineers report 25367 issued 25 November 2025
View this content as a flipbook by clicking here.