` 
 
Glen Gugliotti – CMI 
 
Don Grehan – Unrestricted Building Certifier 
Date of issue:  
19/12/2025 
 
 
Date of expiry:  
18/12/2026 
Certificate number: CM40365-I01-R01 
This certificate is only valid when reproduced in its entirety. 
Page 1 of 8 
 
 
Certification Body: 
ABN: 81 663 250 815 
JASANZ Accreditation 
No. Z4450210AK 
PO Box 273, 
Palmwoods Qld 4555 
Australia 
P: +61 7 5445 2199 
www.cmicert.com.au  
office@cmicert.com.au  
 
Certificate Holder: 
 
Delta Panels Pty Ltd 
ABN: 11 147 861 292 
731 Boundary Road, 
Richlands, QLD, 4077 
Australia  
Ph: 07 3271 2170 
www.deltapanels.com.au   
 
 
 
 
 
Certificate number: CM40365 Rev1 
THIS IS TO CERTIFY THAT 
DeltaCool™-EPS-FR & TPC 
Type and/or use of product: 
Insulated wall panel. 
Description of product:  
DeltaCool™-EPS-FR & TPC are insulated wall panels comprising of either Expanded 
Polystyrene with Fire Retardant (SL Grade EPS-FR) core or Thermosetting Phenolic 
Composite (TPC) core between steel skins. Refer A2 for further information.  
COMPLIES WITH THE FOLLOWING BCA PROVISIONS AND STATE OR TERRITORY VARIATION(S) 
BCA 2022 (Amdt.2) 
 
Volume One 
Volume Two 
Performance Requirement(s): 
Not Applicable 
 
H4P7 
Condensation Management – Refer to Limitation and 
condition 10 
Deemed-to-Satisfy Provision(s): C2D11 (1)(b) & (i) 
Fire Hazard Properties – Walls, Ceiling & Other 
Insulative Material other than sarking - Refer A3 
H1D7(5) 
Roof and wall cladding - Refer to Limitation and 
condition 5 
 
F3D5(1)(c) 
Weatherproofing – Wall cladding 
H2D6(4) 
Weatherproofing – Roof and wall cladding 
 
G5D3 
Construction in bushfire prone areas – Refer A3 and 
Limitation and condition 8 & 9 
H6D2(1)(b)(i) 
Energy Efficiency – Contributes to the overall energy 
efficiency of the building - Refer A3 
 
J4D6 
Energy Efficiency – Contributes to the overall energy 
efficiency of the building - Refer A3 
H7D4 
Construction in bushfire prone areas – Refer A3 and 
Limitation and condition 8 & 9 
State or territory variation(s):  
Not Applicable 
Not Applicable 
SUBJECT TO THE FOLLOWING LIMITATIONS AND CONDITIONS AND THE PRODUCT TECHNICAL DATA IN APPENDIX A AND EVALUATION STATEMENTS IN APPENDIX B 
Limitations and conditions: 
1. This product has not been tested to AS 1530.1-1994 and cannot be considered a non-combustible product. 
2. BCA requires certain external walls, common walls or internal load bearing walls and/or ancillary elements of some Class 2 to 9 buildings to be non-combustible. In 
the absence of site-specific performance solution, this product or system is not suitable for use in these applications where a non-combustible product is required. 
Note, this product can be used as internal and external walls in class 1 & 10 buildings. 
3. The metal wall panels will be limited by wind load shown in the manufacturer’s specifications on the span certified for the product type, thickness, and 
configuration as per the product’s certified span tables. 
Building classification/s: 
Class 1,2,3,4,5,6,7,8,9 & 10 

View this content as a flipbook by clicking here.