October 08, 2024
© 2024 Acronem Consulting Australia Pty Ltd. All rights reserved.
Page 2 of 2
Summary tables of calculations of Total R-value of Delta Panels Phenolic Foam
Composite (TPC) Panels for; External Roof; External Wall; and, Internal Wall
construction performed in accordance with AS/NZS 4859.1:2018 are provided below.
In all cases the construction is assumed to consist of the panel.
The contribution of R-value for the external and internal non-reflective air films have
been added to the R-value contribution of the panel incorporating the effects of mean
temperature for Australian conditions:
- Heat flow out (Winter): Indoors 18°C, outdoors 12°C, mean 15°C
- Heat flow in (Summer): Indoors 24°C, outdoors 36°C, mean 30°C
Contribution of Air-film resistances [(m2.K)/W]
Roof
External Wall
Internal Wall
Wint.
Sum.
Wint.
Sum.
Wint.
Sum.
Outside Air Film
0.04
0.04
0.04
0.04
0.12
0.12
Inside Air Film
0.11
0.16
0.12
0.12
0.12
0.12
Table 2: -
Delta Panels Phenolic Foam Composite (TPC) Panels
Total R-value - External Roof, External Wall & Internal Wall
Australia
Total R-value [(m2.K)/W] (Summer/Winter) & System U-value W/m2K (Summer/Winter)
TPC
Thickness
(mm)
50
60
70
75
80
90
100
110
125
150
175
200
Roof
R(Sum.)
1.45
1.70
1.95
2.05
2.20
2.40
2.65
2.95
3.30
3.90
4.60
5.20
U(Sum.)
0.69
0.59
0.51
0.49
0.45
0.42
0.38
0.34
0.30
0.26
0.22
0.19
R(Wint.)
1.45
1.70
2.00
2.10
2.25
2.50
2.75
3.05
3.40
4.05
4.75
5.40
U(Wint.)
0.69
0.59
0.50
0.48
0.44
0.40
0.36
0.33
0.29
0.25
0.21
0.19
Ext Wall
R(Sum.)
1.41
1.66
1.91
2.01
2.16
2.36
2.61
2.91
3.26
3.86
4.56
5.16
U(Sum.)
0.71
0.60
0.52
0.50
0.46
0.42
0.38
0.34
0.31
0.26
0.22
0.19
R(Wint.)
1.46
1.71
2.01
2.11
2.26
2.51
2.76
3.06
3.41
4.06
4.76
5.41
U(Wint.)
0.68
0.58
0.50
0.47
0.44
0.40
0.36
0.33
0.29
0.25
0.21
0.18
Internal
Wall
R(Sum.)
1.49
1.74
1.99
2.09
2.24
2.44
2.69
2.99
3.34
3.94
4.64
5.24
U(Sum.)
0.67
0.57
0.50
0.48
0.45
0.41
0.37
0.33
0.30
0.25
0.22
0.19
R(Wint.)
1.54
1.79
2.09
2.19
2.34
2.59
2.84
3.14
3.49
4.14
4.84
5.49
U(Wint.)
0.65
0.56
0.48
0.46
0.43
0.39
0.35
0.32
0.29
0.24
0.21
0.18
Faithfully,
Cameron Chick BE(Hons), Ph.D., GC.Com.(Mktg), M.AIRAH, RPEQ
Registered Professional Engineer - Qld. (Structural): 15370, Vic. (Civil): PE0000967
for and on behalf of – Acronem Consulting Australia Pty Ltd
View this content as a flipbook by clicking here.