Early Fire Hazard Properties  AS 1530.3 1989
AWTA Test Reports 21-003527 & 21-003529
Index
Test Range
External Top Skin
Ignitability
0-20
0
Spread of Flame
0-10
0
Heat Evolved
0-10
0
Smoke Developed
0-10
3
Combustibility Test AS 1530.1-1994
CSIRO Report no. FNC12604 dated 8/7/2020 tested five 
(5) samples of the Delta Panels supplied mineral wool 
sample and certified that the material is NOT deemed 
combustible according to the criteria specified in clause 
3.4 of AS 1530.1-1994.
Sotera - FireX™ Car Port System
The Sotera report A21007 J005 - DeltaFireX Car Port 
System FER dw rev 1-4 confirms that the FireX™ Car Port 
System meets the performance requirements of H3P1 
Volume 2, NCC 2022 Amendment 2 when installed in 
accordance with the DeltaFireX Roof Brochure version 
V25.12.04 and section 4.4 of their report as a Class 10a 
structure (car port) attached or adjacent to a Class 1a 
building positioned directly adjacent to the site boundary 
(i.e.) less than 900 mm from the site boundary)
Sotera - Delta MW and 
EPS-FR Awning & Patio Roof System
The Sotera report A21007 J004 - Delta MW and EPS-FR 
Awning and Patio Roof System FER dw rev 1-4, confirms 
that the Mineral Wool & EPS-FR Awning & Patio Roof 
System meets the performance requirements of H3P1 
Volume 2, NCC 2022 Amendment 2 when installed in 
accordance with the Delta Mineral Wool Panels Brochure 
version V25.12.04 and section 4.4 of their report as a Class 
10a structure (car port) attached or adjacent to a Class 1a 
building positioned directly adjacent to the site boundary 
(i.e.) less than 900 mm from the site boundary)
Steel Skin Details Roof
Top Skin
0.42mm / G550 AZ150
Bottom Skin
0.55mm / G300 Z275
Max. Skin Temperature
78oC Dry Heat
Core Material Details
Mineral Wool
Thermal Conductivity
0.042 W/mK @23.0oC
Core Density
100kg/m3
0.6mm Skin Weight 
(kg/m2)
75mm Panel
18.50
100mm Panel 21.00
125mm Panel 23.50
150mm Panel 26.00
R Value
75mm Panel
2.50
100mm Panel
3.30
125mm Panel
4.20
150mm Panel
5.00
Certificate of Conformity CM40435
Sheet Coverage
1000mm - Roof
Length (mm)
Cut to Length Min of 1800mm
Length Tolerance (mm)
5mm+/-
Thickness (mm)
75, 100, 125, 150
Flatness
Standards
0.55mm
Surface deformations 
can be apparent to 
the naked eye when 
observed in certain 
lighting conditions
TECHNICAL SPECIFICATIONS
FIRE TEST PERFORMANCE
- Non-Combustible Insulated Panels
  for Awnings, Patios & Carports
- Technical Details
DeltaTrimTM Fixing Details
Crest fixing only. One fixing every second crest
Panel Thickness (mm)
Fixing into Steel
75
Tek 14 x 150 Hex Head Screw
100
Tek 14 x 175 Hex Head Screw
125
Tek 14 x 200 Hex Head Screw
150
Tek 14 x 230 Hex Head Screw
DeltaOrbTM Fixing Details
Crest fixing only. One fixing every second crest
Panel Thickness (mm)
Fixing into Steel
75
Tek 14 x 135 Hex Head Screw
100
Tek 14 x 150 Hex Head Screw
125
Tek 14 x 175 Hex Head Screw
150
Tek 14 x 200 Hex Head Screw
Fire Test Certificate - AS ISO 9705
Group 1 Classification in accordance with NCC 2022 
Volume One Amendment 2 Clause C2D11 & Clause S7C4 
determined in accordance with AS 5637.1:2015 as per 
Jensen Hughes test report 252674 issued 28 November 
2025 & Spectra Fire Engineers report 25367 issued 25 
November 2025