Glen Gugliotti- CMI
Don Grehan – Unrestricted Building Certifier
Date of issue:
29/01/2026
Date of expiry:
11/05/2028
Certificate number: CM40345-I02-R01
This certificate is only valid when reproduced in its entirety.
Page 1 of 5
Certification Body:
ABN: 81 663 250 815
JAS-ANZ Accreditation
No. Z4450210AK
PO Box 273,
Palmwoods Qld 4555
Australia
P: +61 7 5445 2199
www.cmicert.com.au
office@cmicert.com.au
Certificate Holder:
Delta Panels Pty Ltd
ABN: 11 147 861 292
731 Boundary Road,
Richlands, QLD, 4077
Australia
Ph: 07 3271 2170
www.deltapanels.com.au
Certificate number: CM40345 Rev1
THIS IS TO CERTIFY THAT
DeltaFireX™
Type and/or use of product:
Insulated roof panels with a Mineral Wool core.
Description of product:
Delta FireX™ roof panels incorporates the non-combustible DeltaTrim-MW & DeltaOrb-MW panels. The
panels are available in a 75mm, 100mm, 125mm or 150mm thick and 1000mm wide panel in various
lengths. Refer A2 for details.
COMPLIES WITH THE FOLLOWING BCA PROVISIONS AND STATE OR TERRITORY VARIATION(S)
BCA 2022 (Amdt. 2)
Volume One
Volume Two
Performance Requirement(s):
Not Applicable
Not Applicable
Deemed-to-Satisfy Provision(s): C2D10(6)(g)
Non-combustible building elements
H3D2(g)
Non-combustible materials
C2D11(1)(i)
Fire hazard properties – Group number classification.
Limited to the DeltaTrim-MW Panel Only
H6D2
Energy efficiency – Must be used in conjunction with other
building elements to achieve a Total R Value.
J4D4
Energy efficiency – Must be used in conjunction with
other building elements to achieve a Total R Value.
State or territory variation(s):
Not Applicable
H6D2(VIC)
SUBJECT TO THE FOLLOWING LIMITATIONS AND CONDITIONS AND THE PRODUCT TECHNICAL DATA IN APPENDIX A AND EVALUATION STATEMENTS IN APPENDIX B
Limitations and conditions:
1.
Compliance of DeltaFireX™ Panel with NCC Vol. 2 H3D2(g) is as a non-combustible bonded laminated material.
2.
Construction shall be in strict accordance with the details is A5.
3.
The structural support members are designed and engineered separately as per project requirements by building designers and engineers
and consideration of the requirements of C2D15 Fixing of bonded laminated cladding panels.
4.
When used as an open carport the design needs to consider the requirements of Part 9.2.8 of the ABCB Housing Provisions with the
exception of 9.2.8.(c), (d) & (f)(i), to the satisfaction of the appropriate authority.
5.
The use of the certified product/system is subject to these Limitations and Conditions and must be read in conjunction with the Scope of
Certification below.
Building classification/s:
Class 1,2,3,4,5,6,7,8,9 &10