Glen Gugliotti- CMI Don Grehan – Unrestricted Building Certifier Date of issue: 29/01/2026 Date of expiry: 11/05/2028 Certificate number: CM40345-I02-R01 This certificate is only valid when reproduced in its entirety. Page 1 of 5 Certification Body: ABN: 81 663 250 815 JAS-ANZ Accreditation No. Z4450210AK PO Box 273, Palmwoods Qld 4555 Australia P: +61 7 5445 2199 www.cmicert.com.au office@cmicert.com.au Certificate Holder: Delta Panels Pty Ltd ABN: 11 147 861 292 731 Boundary Road, Richlands, QLD, 4077 Australia Ph: 07 3271 2170 www.deltapanels.com.au Certificate number: CM40345 Rev1 THIS IS TO CERTIFY THAT DeltaFireX™ Type and/or use of product: Insulated roof panels with a Mineral Wool core. Description of product: Delta FireX™ roof panels incorporates the non-combustible DeltaTrim-MW & DeltaOrb-MW panels. The panels are available in a 75mm, 100mm, 125mm or 150mm thick and 1000mm wide panel in various lengths. Refer A2 for details. COMPLIES WITH THE FOLLOWING BCA PROVISIONS AND STATE OR TERRITORY VARIATION(S) BCA 2022 (Amdt. 2) Volume One Volume Two Performance Requirement(s): Not Applicable Not Applicable Deemed-to-Satisfy Provision(s): C2D10(6)(g) Non-combustible building elements H3D2(g) Non-combustible materials C2D11(1)(i) Fire hazard properties – Group number classification. Limited to the DeltaTrim-MW Panel Only H6D2 Energy efficiency – Must be used in conjunction with other building elements to achieve a Total R Value. J4D4 Energy efficiency – Must be used in conjunction with other building elements to achieve a Total R Value. State or territory variation(s): Not Applicable H6D2(VIC) SUBJECT TO THE FOLLOWING LIMITATIONS AND CONDITIONS AND THE PRODUCT TECHNICAL DATA IN APPENDIX A AND EVALUATION STATEMENTS IN APPENDIX B Limitations and conditions: 1. Compliance of DeltaFireX™ Panel with NCC Vol. 2 H3D2(g) is as a non-combustible bonded laminated material. 2. Construction shall be in strict accordance with the details is A5. 3. The structural support members are designed and engineered separately as per project requirements by building designers and engineers and consideration of the requirements of C2D15 Fixing of bonded laminated cladding panels. 4. When used as an open carport the design needs to consider the requirements of Part 9.2.8 of the ABCB Housing Provisions with the exception of 9.2.8.(c), (d) & (f)(i), to the satisfaction of the appropriate authority. 5. The use of the certified product/system is subject to these Limitations and Conditions and must be read in conjunction with the Scope of Certification below. Building classification/s: Class 1,2,3,4,5,6,7,8,9 &10
View this content as a flipbook by clicking here.