DeltaCool-MW is an Insulated Wall Panel System, comprising of two pre-painted, roll-formed steel skins, bonded to a non-combustible mineral wool core. Both skins have a roll-formed tongue and groove edge. Skins are coated with an anti-bacterial paint that inhibits the growth of bacteria. Early Fire Hazard Properties AS 1530.3:1999 AWTA Test Report 18-006075 14-11-20181989 Index Test Range External Top Skin Ignitability 0-20 0 Spread of Flame 0-10 0 Heat Evolved 0-10 0 Smoke Developed 0-10 3 Flameguard FRL Systems Vertical Walls BRANZ Report Number FR1043-001 30/10/2018 Panel Thickness 100mm Maximum FRL -/60/120 Combustibility Test AS 1530.1-1994 CSIRO Report no. FNC12604 dated 8/7/2020 tested five (5) samples of the Delta Panels supplied mineral wool sample and certified that the material is NOT deemed combustible according to the criteria specified in clause 3.4 of AS 1530.1-1994. Non-Combustibility Building Material - NCC Section C1.9 The Delta Panels laminated mineral wool products are certified, by Milanovic Neale Consulting Engineers 28/8/2020, to meet the three performance criteria in the NCC (2019) Section C1.9 (non-combustible building elements) Steel Skin Details ColorBond® Top Skin 0.60mm / G300 Z275 Bottom Skin 0.60mm / G300 Z275 Max. Skin Temperature 78oC Dry Heat Core Material Details Mineral Wool Thermal Conductivity 0.0365 W/mK @23.0oC Adhesive Thermosetting two-part adhesive Core Density 100kg/m3 Panel Weight (kgs/m2) based on 0.6mm steel skins 75mm Panel 18.50 100mm Panel 21.00 125mm Panel 23.50 150mm Panel 26.00 External Wall R Value (m2.K/W) AS/NZS 4859 Parts 1 & 2:2018 Thickness Winter (15o) Summer (23o) 75mm Panel 2.25 2.15 100mm Panel 2.95 2.85 125mm Panel 3.70 3.55 150mm Panel 4.40 4.20 Sheet Coverage 1200mm Length (mm) Cut to Length Min of 1800mm Length Tolerance (mm) 5mm+/- Thickness (mm) 75, 100, 125, 150 Flatness Standards 0.60mm Surface deformations can be apparent to the naked eye when observed in certain lighting conditions Detail A Detail B SPECIFICATIONS -MW -MW Delta Panels Pty Ltd - ABN: 11 147 861 292 E: info@deltapanels.com W: www.deltapanels.com Head Office: 731 Boundary Road, Richlands, Qld 4077 P: +61 7 3271 2170 Sydney Depot: 11 The Old Northern Road, Narellan, NSW 2567 P: +61 2 4611 7712 Version Date: 2025-12-04 Fire Test Certificate - AS ISO 9705 Group 1 Classification in accordance with NCC 2022 Volume One Amendment 2 Clause C2D11 & Clause S7C4 determined in accordance with AS 5637.1:2015 as per Jensen Hughes test report 252674 issued 28 November 2025 & Spectra Fire Engineers report 25367 issued 25 November 2025
View this content as a flipbook by clicking here.