Shear Load Transference - Shear load is transferred by rivets into the floor / ground surface or the perpendicular walls, ceiling & roof at a rate of 1.21 kN per 4.0 mm diameter rivet. Fixing rivets at 200mm centres complies with the 20-minute flame barrier requirements and delivers 14.5 kN of shear capacity transfer per panel (6 on each side) horizontally, and 12.1 kN per metre in vertical joints. Limited by the ability of the panel to transfer the shear. * Figures for 1.2m & 4.8m high panels are extrapolated. It is acceptable to extrapolate Bracing Capacity heights between 1.2m & 4.8m. For heights outside of this dimension range, Diaphragm Analysis is required to establish Bracing Capacity. 0.60mm DeltaSecretFix-TPC Bracing Capacity Panel Height (m) 2.4 1.2* 4.8* Kn/m 5.0 10.0 2.5 Bracing Units (BU) 100 200 50 The above table lists ultimate wind load pressures for strength design and the pressure corresponding to a Span/150 single span deflection for 0.6mm G300 steel skins bonded to a Thermosetting Phenolic Composite (TPC) core and in accordance with Serviceability Limit State criteria as per AS1170.0 - Table C1. The designer shall determine if Span/150 deflection ratio is appropriate for intended use. Loads for a more stringent deflection ratio can be determined by linearly proportioning the loads provided. Differential thermal effects are not incorporated in the loads provided. SPECIFICATIONS -TPC -TPC Detail C 0.6mm DeltaSecretFix-TPC Ultimate Load Capacity / Deflection Load Table (kPa) Panel Thickness (mm) Span (m) 50 75 100 125 150 1.0 1.5 2.0 2.5 2.75 / 1.32 4.14 / 2.44 5.53 / 1.43 3.0 1.90 / 0.97 2.87 / 1.86 3.83 / 2.12 4.40 / 3.49 5.60 / 4.33 3.5 1.39 / 0.74 2.10 / 1.45 2.81 / 2.12 3.42 / 2.81 4.11 / 3.51 4.0 1.06 / 0.56 1.60 / 1.15 2.14 / 1.71 2.61 / 2.29 3.14 / 2.89 4.5 0.83 / 0.61 1.26 / 0.92 1.69 / 1.39 2.06 / 1.89 2.47 / 2.41 5.0 0.67 / 0.35 1.01 / 0.74 1.36 / 1.14 1.66 / 1.57 2.00 / 2.01 5.5 0.54 / 0.27 0.83 / 0.61 1.12 / 0.95 1.37 / 1.32 1.65 / 1.66 6.0 0.45 / 0.22 0.69 / 0.50 0.94 / 0.80 1.14 / 1.12 1.38 / 1.39 6.5 0.59 / 0.42 0.79 / 0.67 0.97 / 0.95 1.17 / 1.18 7.0 0.50 / 0.35 0.68 / 0.57 0.83 / 0.81 1.00 / 1.01 7.5 0.59 / 0.30 0.72 / 0.70 0.87 / 0.88 8.0 0.51 / 0.41 0.63 / 0.61 0.76 / 0.77 8.5 0.55 / 0.53 0.67 / 0.68 As at the stated Version Date all of the information contained in this document is correct. Please check on our WebPage to ensure that you’re referencing the current version. Delta Panels Pty Ltd - ABN: 11 147 861 292 E: info@deltapanels.com W: www.deltapanels.com Head Office: 731 Boundary Road, Richlands, Qld 4077 P: +61 7 3271 2170 Sydney Depot: 11 The Old Northern Road, Narellan, NSW 2567 P: +61 2 4611 7712 Version Date: 2024-10-23
View this content as a flipbook by clicking here.