PANEL LAYOUT
CERTIFICATION LIMITS
HANDLING AND INSTALLATION
DELTADUALCORE™️ PANELS
- For Awning and Patio Roofing that finishes within 900mm of the boundary line.
- Design Configuration
•	
Delta DualCore is limited to a roof covering for Awnings and Patios.
•	
Certification is only for DeltaTrim-DC and DeltaOrb-DC Panel and fixings but not the structure that the panels  
 	
are affixed to.
•	
Any portion of the DeltaTrim-DC and DeltaOrb-DC Panel that is located within the 900mm site boundary must  
	
contain the mineral wool portion of the DeltaTrim-DC and DeltaOrb-DC Panel.
•	
Any portion of the DeltaTrim-DC and DeltaOrb-DC Panel that is located within the 900mm site boundary must  
	
NOT contain any Expanded Polystyrene with fire retardant (EPS-FR) core material.
•	
DeltaTrim-DC or DeltaOrb-DC panels top skin consisting of 0.45 mm Colorbond Steel and bottom skin consisting  
	
of 0.55 mm UniCote Steel.
DeltaDualCore Panels utilises a combination of Expanded Polystyrene with fire retardant (EPS-FR) and Mineral Wool 
(MW) insulated core material. The fibrous structure of Mineral Wool makes it easy to fracture the woven fibres if 
handled and installed incorrectly. Please ensure that correct lifting equipment is used when the panels are transported 
and lifted into position. Refer to the Handling & Installation Manual - Roof Systems for the correct Crane & Sling 
Procedures. 
When installing DeltaDualCore Panels only step onto the section of the panels that are supported by the underneath 
roof structure. Do not step on unsupported spans. The whole of the Mineral Wool section of the panel can not overhang 
the underneath roof structure, it must be fixed and fully supported. Once installed it is classified as trafficable when 
used for maintenance purposes only. The following recommendations should be observed at all times.
Recommendations
•	
Wear flat, rubber soled shoes
•	
Walk over the roof supporting beams avoiding the mineral wool section of the panel
•	
Spread your weight over as many roof crests as possible
•	
Crawl boards must be used when accessing areas not supported by a structure