Delta Panels Pty Ltd - ABN: 11 147 861 292 E: info@deltapanels.com W: www.deltapanels.com Head Office: 731 Boundary Road, Richlands, Qld 4077 | P: +61 7 3271 2170 Sydney Depot: 11 The Old Northern Road, Narellan, NSW 2567 | P: +61 02 4611 7712 Limits For Using Type 1P Awning Classification. Figure 1 - Roof Dimension Following are the dimensional requirements for using Type 1P awning classification, which has 1 partial wall. • For awning dimensions, refer to figure 1. • Awning is to be attached one side only to an existing building. • Awning pitch “α” is to be between 1˚ and 10˚. • Slope of the awning is to be normal to the attached wall. • Minimum hc = 0.05 x d • Maximum hc = 1.0 x d • Maximum hc/wc to be as per Table 1. • Maximum blockage under the roof parallel to the attached wall is to be 56% of the projected area. • Awnings attached one side that do not comply with the above are to be classified as Type 1. • Maximum hc = 1.0 x d • Maximum hc/wc to be as per Table 1. • Maximum blockage under the roof parallel to the attached wall is to be 56% of the projected area. • Awnings attached one side that do not comply with the above are to be classified as Type 1. Skylights & Downlights Skylights