Steel Skin Details
Top Skin
0.42mm / G550 AZ150
Bottom Skin
0.60mm / G300 Z275
Max. Skin Temperature
78oC Dry Heat
Core Material Details
Thermosetting Phenolic Composite
Thermal Conductivity
AS 1366.2/ASTM C 518
Average 0.039 W/mK @23℃
Adhesive
Thermosetting two-part adhesive
Core Density
36kgs/m3 +/- 4kgs
Panel Weight (kgs/m2)
based on 0.6mm steel
skins
50mm Panel
11.70
75mm Panel
12.06
100mm Panel
12.43
125mm Panel
12.79
150mm Panel
13.15
175mm Panel
13.51
200mm Panel
13.86
External Roof
R Value (m2.K/W)
AS/NZS 4859 Parts 1 &
2:2018
Thickness
Winter
(15oC)
Summer
(23oC)
50mm Panel
1.45
1.45
75mm Panel
2.10
2.05
100mm Panel
2.75
2.65
125mm Panel
3.40
3.30
150mm Panel
4.05
3.90
175mm Panel
4.75
4.60
200mm Panel
5.40
5.20
Factory Mutual
FM Approval Class 4880, 4881, 4882 & 4471
Length Tolerance (mm)
5mm +/-
Sheet Coverage (mm)
1000mm, +/-5mm
Length (mm)
Cut to Length Min of 1800mm
Thickness (mm)
50, 75, 100, 125, 150, 175, 200
Minimum Roof Pitch
Building Classes 1-9 - 5º
Building Class 10 - 3º
Flatness
Standards
0.40mm
0.60mm
Surface deformations can be
apparent to the naked eye
when observed in certain
lighting conditions
Patent Application No.
AU2023266264
SPECIFICATIONS
DeltaOrb-TPC is an Insulated Roof Panel System, comprising
of two pre-painted, roll-formed steel skins, wbonded to a
Thermosetting Phenolic Composite core.
The top profile offers striking looks with all of the benefits
of modern Insulated Panel technologies.
The bottom skin has a roll-formed tongue and groove edge.
-TPC
-TPC
Recommendations
• Patios
• Pergolas
• Carports
• Portable Buildings
• Home Extensions
• Commercial Buildings
• Residential Buildings
• Wineries
• Spray Booths
Profiles Available (Underside Skin)
• Smooth & Elegance
Detail A
Detail B
* Conduit receiver track optional addition
*
Due to the nature of the manufacturing process the actual dimensions
may vary. Please refer to the stated acceptable tolerances allowances.
Early Fire Hazard Properties AS 1530.3:1999
AWTA Test Report 23-000591 20-02-2023
Index
Test Range
External Top Skin
Ignitability
0-20
0
Spread of Flame
0-10
0
Heat Evolved
0-10
0
Smoke Developed
0-10
1
Fire Test Certificate - AS ISO 9705
Group 1 Classification in accordance with NCC Volume
One Specification BCA2022 C2D11 & Specification
7, Fire Hazard Properties, Clause S7C4 determined in
accordance with AS 5637.1:2015 as per BRANZ test report
FI6323-01-2 issued 23rd February 2021
Bushfire Attack Level - BAL 29
DeltaOrb-TPC has achieved a Bushfire Attack Level
(BAL) of AA29 as per the CSIRO Bushfire performance
assessment report FCO-3534, of Delta Panel roof systems
in accordance with AS1530.8.1:2018
Delta Panels Pty Ltd - ABN: 11 147 861 292
E: info@deltapanels.com
W: www.deltapanels.com
Head Office: 731 Boundary Road, Richlands, Qld 4077 P: +61 7 3271 2170
Sydney Depot: 11 The Old Northern Road, Narellan, NSW 2567 P: +61 2 4611 7712
Version Date: 2025-11-28