Use Cyclone Plate and Neo Washer on each fixing.
Upon Installation the overlap needs to be stitch screwed or riveted every 300mm.
As at the stated Version Date all of the information
contained in this document is correct. Please check
on our WebPage to ensure that you’re referencing the
current version.
SPECIFICATIONS
Single Spans (mm)
Wind
Category
Panel
Thickness
3 Sides
Open
2 Sides
Open
1 Side
Open
Fully
Enclosed
N2
(W33)
75
7380
5630
4190
5250
100
7500
68860
4900
6330
150
9000
7780
5740
7230
N3
(W41)
75
5270
4070
3060
3810
100
6360
4740
3430
4390
150
7270
5570
4150
5190
N4
(W50)
75
3960
3080
2330
2880
100
4590
3450
2510
3200
150
5410
4170
3130
3900
DeltaTrim-TPC Acoustic Values
Frequency
50mm
125mm
100
15.41
15.00
160
16.40
15.09
200
18.81
17.70
250
19.70
18.51
315
21.39
19.40
400
22.31
19.69
630
23.40
19.10
800
23.69
17.31
1000
25.61
18.29
1250
21.01
30.10
1600
20.00
36.19
2000
34.79
37.30
2500
41.70
37.09
3150
44.10
35.69
5000
44.61
39.90
STC
24.00
23.00
RW
25.00
24.00
Detail A
-TPC
-TPC
Delta Panels Pty Ltd - ABN: 11 147 861 292
E: info@deltapanels.com
W: www.deltapanels.com
Head Office: 731 Boundary Road, Richlands, Qld 4077 P: +61 7 3271 2170
Sydney Depot: 11 The Old Northern Road, Narellan, NSW 2567 P: +61 2 4611 7712
Version Date: 2025-11-28
Acoustic Performance
Acoustic testing has been performed on TPC panels in compliance
with the requirements of AS 1191-2002 “Acoustics - Method for
Laboratory Measurement of Airborne Sound Insulation of Building
Elements”.
The procedures specified by AS/NZS ISO 717.1:2024 were used to
calculate the Sound Transmission Class (STC) and the Weighted
Sound Reduction Index Rw = 25 dB.
Trafficable Status
DeltaTrim-TPC is classified as trafficable when used for maintenance
purposes. The following recommendations should be observed at all
times.
• Wear flat, rubber soled shoes
• Walk over the roof supporting beams
• Spread your weight over as many roof crests as possible
• Crawl boards should be used when accessing areas not
supported by a structure
Aesthetics
Roll-formed metal sheeting as utilised in DeltaTrim™ Insulated
Panels may exhibit waviness, commonly referred to as “oil-
canning.” The degree of oil-canning will vary depending on factors
such as the panel’s length, colour and exposure to sunlight. Oil-
canning pertains to aesthetics only and has no adverse effect
on the structural performance of the panels. Delta Panels is not
responsible for oil-canning or aesthetics. Oil-canning shall not be
grounds to withhold payment or reject panels.
DeltaTrim-TPC Fixing Details
Crest fixing only. One fixing every second crest
Panel
Thickness
(mm)
Fixing into Steel
Fixing into Timber
50
Tek 14 x 135 Hex Head Screw T17 14 x 125 Hex Head Screw
75
Tek 14 x 150 Hex Head Screw T17 14 x 150 Hex Head Screw
100
Tek 14 x 175 Hex Head Screw T17 14 x 175 Hex Head Screw
125
Tek 14 x 200 Hex Head Screw T17 14 x 200 Hex Head Screw
150
Tek 14 x 230 Hex Head Screw T17 14 x 230 Hex Head Screw
175
Tek 14 x 260 Hex Head Screw T17 14 x 265 Hex Head Screw
200
Tek 14 x 260 Hex Head Screw T17 14 x 300 Hex Head Screw
View this content as a flipbook by clicking here.