DeltaCool-TPC is an Insulated Wall Panel System,
comprising of two pre-painted, roll-formed steel skins,
bonded to a Thermosetting Phenolic Composite core.
Both skins have a roll-formed tongue and groove edge.
Skins are coated with an anti-bacterial paint that inhibits
the growth of bacteria.
Early Fire Hazard Properties AS 1530.3:1999
AWTA Test Report 23-000591 20-02-2023
Index
Test Range
External Top Skin
Ignitability
0-20
0
Spread of Flame
0-10
0
Heat Evolved
0-10
0
Smoke Developed
0-10
1
Steel Skin Details
Top Skin
0.40mm / 0.60mm / G300 Z275
Bottom Skin
0.40mm / 0.60mm / G300 Z275
Max. Skin
Temperature
78oC Dry Heat
Core Material Details
Thermosetting Phenolic Composite (TPC)
Thermal Conductivity
AS 1366.2/ASTM C 518
Average 0.039 W/mK @23℃
Core Density
36kgs/m3 +/- 4 kgs
Panel Weight (kgs/m2)
based on 0.6mm steel
skins
50mm Panel
11.70
75mm Panel
12.06
100mm Panel
12.43
150mm Panel
13.15
200mm Panel
13.84
External Wall
R Value (m2.K/W)
AS/NZS 4859 Parts 1
& 2:2018
Thickness
Winter (15oC)
Summer (23oC)
50mm Panel
1.46
1.41
75mm Panel
2.11
2.01
100mm Panel
2.76
2.61
150mm Panel
4.06
3.86
200mm Panel
5.41
5.16
Factory Mutual
FM Approval Class 4880, 4881 & 4882
Certificate of
Conformity
CodeMark Australia Certificate - CM40365
Sheet Coverage (mm)
1200mm
Length (mm)
Cut to length. Minimum of 1800mm +/-5mm
Thickness (mm)
50, 75, 100, 150, 200
Flatness
Standards
0.40mm
0.60mm
Surface deformations can be
apparent to the naked eye when
observed in certain lighting
conditions
Patent
Application No.
AU2023266264
Recommendations
• Cold Stores
• Commercial Kitchens
• Food Processing Areas
• Portable Buildings
• Home Extensions
• Spray Booths
• Wineries
• Commercial Buildings
• Residential Buildings
• Growing Rooms
Profiles Available
• Smooth
• Ribbed
• MicroRibbed
• 5V
• SingleV
Detail A
Detail B
SPECIFICATIONS
-TPC
-TPC
Fire Test Certificate - AS ISO 9705
Group 1 Classification in accordance with NCC Volume
One Specification BCA2022 C2D11 & Specification 7,
Fire Hazard Properties, Clause S7C4 determined in
accordance with AS 5637.1:2015 as per BRANZ test
report FI6323-01-2 issued 23rd February 2021
Bushfire Attack Level - BAL 29
DeltaCool-TPC achieved a Bushfire Attack Level (BAL)
of AA29, as per CSIRO report Number FSZ2373 issued
9 June 2023, when tested in accordance with the test
method AS 1530.8.1
CodeMark
CodeMark Australia Certificate CM40365
certifies that DeltaCool-TPC complies
with the stated performance provisions
of the BCA 2022 (Amendment 2). Please
refer to the certificate as displayed on
our web page for the exact details of the
compliance.
Delta Panels Pty Ltd - ABN: 11 147 861 292
E: info@deltapanels.com
W: www.deltapanels.com
Head Office: 731 Boundary Road, Richlands, Qld 4077 P: +61 7 3271 2170
Sydney Depot: 11 The Old Northern Road, Narellan, NSW 2567 P: +61 2 4611 7712
Version Date: 2025-12-17